Send SMS
Send E-mail

Industrial Modbus TCP Terminal Server

Modbus is an industry adopted communication protocol based on RTU, ASCII, and TCP protocols for various applications; these three protocols are commonly used by various equipments in the industry, such as DCS, PLC, HMI, power meters, various sensor and measuring instruments.
Get CALLBACK

4 Port Isolated Modbus Gateway

4 Port Isolated Modbus Gateway
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
BrandSan Telequip
ModelSC10E4I M
Humidity5 to 95 % RH (non condensing)
Storage Temperature-40 to +85 Degrees C
Operating Temperature-40 to +80 Degrees C
Weight900 gm
MountingDIN rail
Dimensions53.4 x 119.9 x 145.7 mm
Power Consumption5.85 W
Serial Port Type5 Pin Lockable Screw Type Terminals
Mean Time Before Failure188251 hours / 21.5 years
ESD Protection15 KV
Surge Protection800 W
Date Rate1200 bps to 921 Kbps, Support user define baud rate
Multidrop Number32 devices on each port

Modbus is an industry adopted communication protocol based on RTU, ASCII, and TCP protocols for various applications; these three protocols are commonly used by various equipment in the industry, such as DCS, PLC, HMI, power meters, various sensor and measuring instruments. The SC10E4I M supports 16 simultaneous TCP master and 32 simultaneous requests for each TCP master. Each Serial port can be individually configured for Modbus RTU or Modbus ASCII, Master or Slave or even different baud rate.

There are 2 Ethernet ports and they operate as:
Dual Subnet Mode: Two Ethernet ports have separate IP addresses and subnets
Redundancy Mode: The system will use only one port for data transfer. If the port is disconnected, the whole system will change to another port automatically

SC10E4I M Gateway supports:
1. RS485/422 and Ethernet
2. Conversion of any Modbus protocols between Modbus TCP, Modbus RTU, and Modbus ASCII
3. ID routing when a Modbus ID conflict occurs
4. Function Codes supported : 1, 2, 3, 4, 5, 6, 15 & 16

Additional Information:
  • Item Code: SC10E4IM
Yes! I am Interested
View PDF
Get CALLBACK

4 Port Modbus TCP Gateway

4 Port Modbus TCP Gateway
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
BrandSan Telequip
Serial Ports4-Port; DB9 Male connector
Mean Time Before Failure188251 hours / 21.5 years
ESD Protection15 KV
ModelSC10E4NI M
Weight900 gm
EnclosureDIN Rail
Dimensions53.4 x 119.9 x 145.7 mm
Operating Temperature-40 to +80 Degrees C
Storage Temperature-40 to +85 Degrees C
Humidity5 to 95 % RH (non condensing)
Power Consumption5.85 W

The SC10E4 M Series support 16 simultaneous TCP master and 32 simultaneous requests for each TCP master. Each RS232/485/422 serial port can be individually configured for Modbus RTU or Modbus ASCII, Master or Slave or even different baud rate.

There are 2 Ethernet ports and they operates:
  • Dual Subnet Mode: Two Ethernet ports have separate IP addresses and subnets
  • Redundancy Mode: The system will use only one port for data transfer. If the port is disconnected, the whole system will change to another port automatically

 

Technical Details:

Operating Temperature-40 to +80 Degrees C
Storage Temperature-40 to +85 Degrees C
Humidity5 to 95 % RH (non condensing)
Dimensions53.4 x 119.9 x 145.7 mm
Weight900 gm
EnclosureDIN Rail

Additional Information:
  • Item Code: SC10E4NIM
Yes! I am Interested
View PDF
Get CALLBACK

8 & 16 Port Modbus TCP Gateway

8 & 16 Port Modbus TCP Gateway
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
BrandSan Telequip
Dimensions436 mm x 200 mm x 43.5 mm
Heat Load34.12 BTU/hr
CPU32-bit 266MHz RISC Processor with MMU
Flash2+ 8MB (2MB for Boot loader)
RAM32 Mbytes DDR
EEPROM8K Bytes
WatchdogHardware built-in
Ethernet ComplianceIEEE 802.3
Ethernet Transmission Rate10/100Mbps Auto-detection
Isolation1.5 KV Magnetic Isolation
ModelSC10E08AM & SC10E16AM
Input Power SupplyAC 100-260V, 24V DC & 48V DC options are also available
Driver SupportWindows 2008, 2007, 98/200/NT/XP/2003/Vista
Serial InterfaceRS232/422/485 software selectable
Serial Ports8 / 16 port
Baud Rate300 bps to 921 Kbps
Power ConsumptionMax. 8.5 W
Weight3200 gm

Modbus is an industry adopted communication protocol based on RTU, ASCII and TCP protocols for various applications. These three protocols are commonly used by various equipment's in the industry, such as DCS, PLC, HMI, power meters, various sensor and measuring instruments. The SC10E16AM Series support 16 simultaneous TCP master and 32 simultaneous requests for each TCP master.
Yes! I am Interested
View PDF