Isolated Serial Redundancy Switch

Isolated Serial Redundancy Switch
 
Get Best Quote
Approx. Rs 17,825 / Piece
Get Latest Price
Product Brochure

Product Details:
Model NumberSAM 201I
Mounting TypePanel Mounting or DIN Rail
BrandSan Telequip
Baud RateUp to 115kbps
Isolation3 KV
ProtocolsMODBUS,ASCII,IEC 101,IEC 103 etc
Connector - OutputDB9 Male
Mode SelectionAuto / Manual through Membrane Key
Connector - InputDB9 Female
Voltage230 V AC
Communication Ports3. RS232,RxD,TxD,GND

It can enable 2 Modbus Masters talk to a common RTU or a single Modbus Master to talk to Redundant RTU’s on field. During Power On, whichever Master sends a query, is connected to the Output (Slave). Incase your Master Port fails or Cable from your Primary Master to our Port has failed then SAM senses “No Communication” between the Primary Master & the Slave & seamlessly switches communication to your Secondary Master. Time Out is selectable from 1 Sec. to 1 min. This timeout is factory set. SAM will wait upto the Time Out in order to establish other connection. Manual selection of the Primary & Secondary Master is also provided for easy diagnostics. It is expected that during the failure of Primary Master connection, your Secondary master will start sending the queries. Alternatively the Switch can also be used for communication between 2 Slaves & 1 Master. The query from a Master can be broadcasted to both the Slaves but only 1 Slave need to respond at a time. This is in cases where the Slaves are Redundant. SAM 201I has been designed to cater to the requirement of Sharing / offering Redundancy for the Serial Ports. It is Protocol independent with all the 3 Ports are RS232. All the 3 Serial ports are 3KV Optically Isolated.
Yes! I am Interested
Get CALLBACK

Serial Redundancy Switch.

Serial Redundancy Switch.
 
Get Best Quote
Approx. Rs 20,125 / Piece
Get Latest Price
Product Brochure

Product Details:
BrandSan Telequip
Model Name/NumberSRS 201M
Baud Rate9600, 19200, 38400,115200
ConnectorsRS485 Ports : 6 Pin Terminal block
Voltage24V DC
Data bits8 (fixed)
No. of Ports3
Modes of Operation3 (Auto Slave, Auto Master, Manual), selection by DIP switch
Communication PortEach port can be connected RS485 2 Wire
ProtocolMODBUS, ASCII, IEC 101, IEC 103

Many applications in Industrial PLC or SCADA communication require multiple Slave devices to be shared with 2 (two) Masters. Alternatively, Single Master wants to communicate with multiple slave devices. Serial Redundancy Switch (SRS) has been designed to cater to this specific requirement. It is Protocol independent & has different operating modes. The Serial communication parameters are field selectable using DIP switch. All ports of this product are RS485 2 Wire with built in termination resistor. This product does not act as protocol converter gateway. It acts as Hub or Splitter switch for RS485 ports.
Yes! I am Interested
Get CALLBACK

SRS 201 Serial Redundancy Switch

SRS 201 Serial Redundancy Switch
 
Get Best Quote
Approx. Rs 20,125 / Piece
Get Latest Price
Product Brochure

Product Details:
BrandSan Telequip
Model Name/NumberSRS 201
Baud RateUpto 115kbps
Mode of OperationAuto / Manual.
Voltage230V AC
Signals3 signals for RS232 & 2 or 4 for RS485/RS422
Time OutUser Programmable through Serial Port. Default : 1 sec

Offering communication Redundancy has taken roots. There is a felt need to communicate SCADA PC / HMI / DCS etc with Redundant Controllers / PLC / RTU’s / IED devices etc. SRS has been designed to cater to this requirement of the industry. It is Protocol independent & all the 3 Ports are RS232 / RS485 / RS422 configurable.

Other Details
It can enable 2 SCADA Masters talk to a common RTU or a single SCADA master to talk to Redundant RTU’s on field. It can also be connected through a PLCC modems etc.

During Power On, whichever Master sends a query, is connected to the Output ( Slave ). Incase your Master Port fails or Cable from your Primary Master to our Port has failed then SRS senses “No Communication” between the Primary Master & the Slave & bumpless switches communication to your Secondary Master. Time Out is selectable from 1 Sec. to 9 Sec. SRS will wait upto the Time Out in order to establish other connection. Manual selection of the ports is provided for easy diagnostics.

Alternatively the Switch can also be used : 
  • For communication between 2 Slaves & 1 Master. The query from a Master can be broadcasted to both the Slaves but only 1 Slave need to respond at a time. This is in cases where the Slaves cannot be multidropped.
  • To create cable level redundancy for devices having only a Single Serial port. 