Send SMS
Send E-mail

BMS Protocol Converter

BMS Converter is an external Building and Industrial Automation multi-protocol device server for OEMs wanting to provide protocol translation between Serial-Serial, Serial-Ethernet and Ethernet-
Ethernet devices using Lon Works®, BACnet, Metasys N2, Modbus.
Get CALLBACK

BMS Protocol Converter

BMS Protocol Converter
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
BrandSan Telequip
Model Name/NumberGWBMS
Ethernet Port1. 10/ 100 Ethernetport
IndicationsLEDs for Tx, Rx, Power
Power24 VAC/ DC, Range 18 to 72V DC. 100mA @ 24V
Connector3 Pin Screw type
Operating Temperature-40 to 85 Degree C
Relative Humidity5-90% RH, (Non-condensing)
Dimensions46 x 70 x 111 mm

MODEL NO.PROTOCOLS
GWBMS01Modbus RTUBACnet IP
GWBMS01-02Modbus RTU 2 RS485 PortsBACnet IP
GWBMS02BACnet MSTPBACnet IP/ Modbus TCP / Ethernet IP
GWBMS02-02R BACnet ROUTERBACnet MSTP 2 RS485 portsBACnetBACnet IP
GWBMS03Lon WorksBACnet IP / Modbus RTU / Modbus TCP
GWBMS04-AModbus RTU /BACnet MSTPMetasysN2
GWBMS04-BMetasysN2BACnet IP
GWBMS04-B-02MetasysN2 2 RS485 PortsBACnet IP
GWBMS04-DBACnet MSTPModbus RTU
GWBMS05-ABACnet IPModbus TCP
GWBMS05-BSNMPBACnet IP/ Modbus TCP
GWBMS05-CSNMPModbus RTU/BACnet MSTP

BMS Converter is an external Building and Industrial Automation multi-protocol device server for OEMs wanting to provide protocol. Translation between Serial-Serial, Serial-Ethernet and Ethernet-Ethernet devices using Lon Works, BACnet, MetasysN2, Modbus and more. The Converter includes all the hardware and software to enable the customer’s products to interface to various networks Each BACnet. The converter is provided with the necessary protocol drivers Multiple drivers can be installed on a single Converter. We can provide custom driver support when needed.

Features:
  • The most flexible and versatile multi-protocol Device Server on the market
  • Supports virtual nodes allowing multiple OEM controllers to connect to a single. Converter and seen as separate controllers on the various field networks
  • TRUE protocol translation and not Protocol packet Encapsulation
  • Interfaces too ver85 Building and Industrial Automation Protocols
  • Multi-Client and Multi-Server support ensures interoperability between any Industrial and or Building Automation protocols
  • Flash upgradeable

Additional Information:
  • Item Code: GWBMS
Yes! I am Interested
View PDF
Get CALLBACK

M-Bus Protocol Gateway

M-Bus Protocol Gateway
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
BrandSMC
ModelFS-QS
Hardware InterfacePhoenix Connector
Power Consumption5-15 W
Baud Rate300-38400 baud (Auto-band Discovery)
IsolationGalvanic Isolation

The M-Bus QuickServer Gateway from Sierra Monitor easily enables data access between M-Bus networks and devices and other networks that utilize open and proprietary protocols such as BACnet, Modbus, LonWorks, Metasys N2 by JCI, SNMP and more. With over 100 protocols available in the extensive FieldServer Driver Library, no other product can connect M-Bus to more products! Sierra Monitor is a leader in protocol gateways for the building automation industry, enabling system integrators and developers to prepare building automation and process control infrastructures for the future by breaking down protocol barriers. FieldServer is in thousands of installations with over 700 translation paths. These gateways are LonMark certified, BACnet BTL Marked, Metasys compatible and mission-critical tested. M-Bus is a European standard for remote reading of various consumption meters such as gas meters, water meters and heat meters. The M-Bus QuickServer Gateway is configurable to act as both a Master and a Slave M-Bus device. As an M-Bus Master the number of devices supported is limited to up to 64 devices as the FieldServer provides power to the M-Bus. The M-Bus master interrogates the slave devices as the gateway acts as a Client. It will request information from the slave devices and receive and process only the expected responses. As an M-Bus Slave the maximum number of devices on the M-Bus is limited to the M-Bus standard of 250. The gateway will act as an M-Bus Slave and will respond only to requests from the M-Bus master devices.

Features:
  • Auto Baud Discovery: The FieldServer configured as an M-Bus Master device has the ability to change each slave to a desired standard M-Bus baud rate automatically. The FieldServer configured as an M-Bus device has the ability to change its own baud to a desired standard M-Bus baud rate if requested by the Master. (Auto Baud Discovery set Slaves to any supported baud rate)

Additional Information:
  • Item Code: Mbus-Gateway
Yes! I am Interested
View PDF
Explore More Products
X
Find Us Machindra Phale (Senior Executive) Deron Heights, 5th Floor, Office No. 504 & 505, Survey No. 270/1/23 Baner Road, Pune - 411045, Maharashtra, India
SEND SMS
SEND E-MAIL